H100

H100

The LSLV-H100 sets the standard for the drive industry. Environmentally friendly water treatment and Fan and Pump systems incorporate the outstanding energy-saving benefits of the LSLV-H100 for fans and pumps.

Category:




Features

1. Maximized User Convenience

Communication Module

  • RS-485 Capability is built-in
  • Modbus-RTU, Metasys N2
  • BACnet MS/TP is embedded as standard
  • LonWorks option can be added

DC Reactor

A built-in DC reactor to improve power factors and reduce THD is installed.

  • DC Reactor built-in as a standard for 400V 37-90kW

Built-in EMC Filter

A built-in EMC filter to respond to the specifications for noise reduction

    • 400V 0.75~30kW Built-in as default (C3)
    • 400V 37~55kW Built-in option can be selected (C3)
    • LonWorks option can be added

※ 75~90kW satisfies EMC specifications even without a filter

Compliant​ with Global

SpecificationsA built-in EMC filter to respond to the specifications for noise reduction UL
Plenum Rated

Communication Module

  • RS-485 Capability is built-in
  • Modbus-RTU, Metasys N2
  • BACnet MS/TP is embedded as standard
  • LonWorks option can be added

DC Reactor

A built-in DC reactor to improve power factors and reduce THD is installed.

  • DC Reactor built-in as a standard for 400V 37-90kW

Built-in EMC Filter

A built-in EMC filter to respond to the specifications for noise reduction

    • 400V 0.75~30kW Built-in as default (C3)
    • 400V 37~55kW Built-in option can be selected (C3)
    • LonWorks option can be added

※ 75~90kW satisfies EMC specifications even without a filter

Compliant​ with Global

SpecificationsA built-in EMC filter to respond to the specifications for noise reduction UL
Plenum Rated

Keypad Exclusive for HVAC

Used to issue commands, configure drive parameters, and for monitoring drive status

  • HAND Mode: Used when selecting frequency or run/stop commands.
  • AUTO Mode: Drive operated using the keypad. Multifunctional terminal block and
    communications.

Easy to Change Cooling Fan

It is easy to change the cooling fan without opening the cover of the drive

Flange Type

If the space is too small, a heat sink can be installed outside the panel

Keypad Exclusive for HVAC

Used to issue commands, configure drive parameters, and for monitoring drive status

  • HAND Mode: Used when selecting frequency or run/stop commands.
  • AUTO Mode: Drive operated using the keypad. Multifunctional terminal block and
    communications.

Easy to Change Cooling Fan

It is easy to change the cooling fan without opening the cover of the drive

Flange Type

If the space is too small, a heat sink can be installed outside the panel

Smart Copier

Data Flow in Smart Copier

  • Power-free Operation
  • LED Feedback
  • Parameters Read/Write
  • Easy to Install

2. Efficient Use of Space

The size of the control board is significantly reduced when multiple drives are installed by
minimizing the distance between produ
cts installed

※Side-by-side installation is unavailable for 37~90kW
Main components are optimally deployed through thermal radiation analysis and 3D design to reduce
size by 34% compared to iP5A (Volume based).

3. Stable System Control

LSLV-H100 drives are intelligent drives equipped with various protective
and operation functions for continuous stable operation in response to external environmental changes.

Soft Fill Operation

Prevents pump damage caused by extreme pressure change during initial
operation of pumps or inside pumps.

Lubrication Control

When a control command is made in the Flow/Oiling Systems, lubrication
signals are output for a certain period before the motors are started. Drive control immediately
begins form the signal output point until the signals are turned off after the set time

Start Ramp & End Ramp

Prevents pump damage by changing ramps using the
acceleration/deceleration time setting upon initial pump operation

Damper Control

When a damper exists in the system configuration, the drive will
command the damper to open/close or receive feedback signals for protection.

Dec Valve Ramp

Prevents pump and pipe damage caused by sudden pressure changes when
pumps are stopped or a pump valve is closed, Deceleration time may be set.

Detection of Pipe Broken

Upon PID operation, pipe damages or leakage is detected to display a
warning or a trip.

Multi Motor Control

MMC is used when a single drive is used to control multiple
motors in the pump system. It can control 1 main motor and 5 auxiliary motors.

Level Detection

When the drive is operated under a frequency that is beyond the
set frequency and source (voltage, current, and etc.) values to be detected are above or
below the user set values, it generates a trip or activates a relay for protective operation

Scheduling (Time Event: Real Time Clock)

Prevents pump damages caused by dramatic pressure changes during
initial operation or pumps or inside pumps.

Pre-Heat

Pre-heats motors by direct current output when the motors are
at fixed state of time in order to prevent condensation in the motors

Flow Compensation

Compensates for hydraulic loss that occurs when the length of
pipes are too long, adding a compensation rate depending on the inverter output
frequency.

Under Load Protection

When running pumps including no flow and dry pumps under the
set frequency, the drive issues a warning function and when the trip is generated,
free-run, deceleration, or stop can be selected

Energy-saving Display (Payback Counter)

Commercial energy consumption is compared to the amount
of energy used by the drive to calculate the amount of energy saved.

Macro Setting

If a particular application is selected, frequently used
parameters and set values are changed and registered in a macro group.

Power-on Resume

When the drive restarts after it was stopped due to power
interruption upon communication control, ‘Power-on Resume’ is used to follow the
previous control command.

KEB, Kinetic Energy Buffering

Upon loss or momentary interruption of input power,
if the KEB is set, the drive maintains a DC Link Voltage using regenerated
energy from the motor during the interruption period.

Sleep, Sleep Boost, Wake-up

It is used to put the drive on standby and restarts
it using the amount of energy used by the drive to calculate the amount of
energy saved.

Pump Clean

Upon pump operation, the efficiency of pumps may
decline when foreign substances are stuck in an impeller. The pump clean removes
foreign substances to extend pump life.

Auto Torque Boost

The drive outputs voltage for the drive by
controlling the level of boost to fit the load by itself.

Load Tuning

Establishes load (current & power) curves
based on drive frequency so as to make load characteristics curve required
for ‘Under Load’ and ‘Pump Clean.’

Aux Motor PID Compensation

Pipe flow increases and conduit pressure
decreases as the number of auxiliary motors increases. The ‘Aux Motor PID
Compensation’ is used to compensate pressure loss suitable for the given
motor when operating auxiliary motors.

Fire Mode

When an emergency such as a fire occurs at the
suction/exhaust fans, but the hardware did not fail nor has a critical
defect, the drive continuously operates to protect other systems under the
set frequency and direction.

Frame Design

Type Designation

Dimension

Specification

3-Phase 200V (0.75~18.5kW)

LSLV ㅁㅁㅁㅁ S100-4 ㅁㅁㅁㅁ 0300 0370 0450 0550 0750
Motor Rating Heavy
Duty(HD)
[HP] 40.0 50.0 60.0 75.0 100.0
[kW] 30.0 37.0 45.0 55.0 75.0
Heavy
Duty(HD)
[HP] 50.0 60.0 75.0 100.0 120.0
[kW] 37.0 45.0 55.0 75.0 90.0
Output Rating Capacity
[kVA]
Heavy
Duty(HD)
46 57 69 84 116
Normal
Duty(ND)
55 67 78 106 126
Rated
Current
[3-Phase input] (A)
Heavy
Duty(HD)
61.0 75.0 91.0 110 152.0
Normal
Duty(ND)
75 91 107 142 169.0
Rated
Current
[Single-Phase input] (A)
Heavy
Duty(HD)
32 39 47 57 78
Normal
Duty(ND)
39 47 55 73 87
Frequency [Hz] 0~400Hz (IM Sensorless : 0~120[Hz])
Voltage [V] 3-phase 380~480V
Input Rating Voltage [V] 3-Phase 380~480VAC (-15%~+10%)
Single-Phase 200~240VAC (-5%~+10%)
Frequency [Hz] 50~60Hz ( ±5%)
(In case of single phase input, input frequency is only 60Hz
(±5%))
Rated
Current [A]
Heavy
Duty(HD)
56.0 69.0 85.0 103.0 143.0
Normal
Duty(ND)
69.0 85.0 100.0 134.0 160.0
Weight [kg] 25.8 34.4 34.4 41.8 43.8

· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04)
setting

3-Phase 400V (0.75~22kW)

Model Name LSLV ㅁㅁㅁㅁH100-4 ㅁㅁㅁㅁ 0008 0015 0022 0037 0055 0075 0110 0150 0185 0220
Applied Motor [HP] TBD 7.5 10 15 20 25 30
[kW] 5.5 7.5 11 15 18.5 22
Rated Output Rated Capacity (kVA) 9.1 12.2 18.3 23 29.0 34.3
Rated Current 12 16 24 30 38 45
Output Frequency 0~400Hz
Output Voltage (V) 3-Phase 200~240V
Rated Input Service Voltage (V) 3-Phase 200~240VAC (-15%~+10%)
Input Frequency 50~60Hz ( .5%)
Rated Current (A) 12.2 17.5 26.5 33.4 42.5 50.7
Weight [kg] 3.3 3.3 3.4 4.6 4.8 7.5

· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04)
setting

3-Phase 400V (30.0~90.0kW)

Model Name LSLV ㅁㅁㅁㅁH100-4 ㅁㅁㅁㅁ 0300 0370 0450 0550 0750 0900
Applied Motor [HP] 40 50 60 75 100 125
[kW] 30 37 45 55 75 90
Rated Output Rated Capacity (kVA) 46.5 57.1 69.4 82.0 108.2 128.8
Rated Current 61 75 91 107 142 169
Output Frequency 0~400Hz
Output Voltage (V) 3-Phase 380~480V
Rated Input Service Voltage (V) 3-Phase 380~480VAC (-15%~+10%)
Input Frequency 50~60Hz ( .5%)
Rated Current (A) 69.1 69.3 84.6 100.1 133.6 160.0
Weight [kg] 7.5 26 35 35 43 43

· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04)
setting

3-Phase 400V (110.0~500.0kW)

Model Name LSLV ㅁㅁㅁㅁH100-4 ㅁㅁㅁㅁ 0300 0370 0450 0550 0750 0900
Applied Motor [HP] 40 50 60 75 100 125
[kW] 30 37 45 55 75 90
Rated Output Rated Capacity (kVA) 46.5 57.1 69.4 82.0 108.2 128.8
Rated Current 61 75 91 107 142 169
Output Frequency 0~400Hz
Output Voltage (V) 3-Phase 380~480V
Rated Input Service Voltage (V) 3-Phase 380~480VAC (-15%~+10%)
Input Frequency 50~60Hz ( .5%)
Rated Current (A) 69.1 69.3 84.6 100.1 133.6 160.0
Weight [kg] 7.5 26 35 35 43 43

· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04)
setting

 